Electric Water Heaters - How They Work with DiagramsWater heaters - How electric water heaters work in detail complete with diagramsA electric water heater is a less prevalent type of
heater than gas. They heat water about half as fast and cost about twice as much
to run. Electricity is expensive.
Most of us take our water heater for granted. At
first glance there doesn’t seem to be much of interest. After all, it’s
basically an insulated tank full of water with a gas flame under it.
Add a thermostat, a pressure temperature relief valve, a dip tube, a
drain valve, and you’ve got a water heater! Sometimes water heaters behave in some interesting
ways and can be puzzling when something goes wrong.
Let’s examine how an electric water heater works. A typical 50 gallon heater consists
of a tall cylindrical tank, surrounded with insulation, and enclosed in a sheet
metal outer shell. Usually the electrical connections are made on the top
where there is a conduit fitting. Most electric water heaters have two thermostats, an upper and a
lower. Typically the top and bottom electric heating elements each have their
own thermostat and are wired in such a way that only one heating element heats
up at a time. Normally the it's the upper thermostat that switches on first, and when the
upper portion of the water is hot, the upper thermostat sends the electricity to the lower thermostat and element. If
the lower thermostat is below the set point, then the lower heating element
turns on.
If the water in the tank gets too hot, it will trip the high limit switch, (a circuit
breaker). The high limit switch is located in the upper thermostat, and it usually has a red
reset button. In order to get it working again the high limit switch must be manually
reset by pushing in the red button.
At the inlet to the water heater there is what is
called a “Dip tube”. The dip tube is a long skinny plastic tube that
reaches down to the bottom of the tank. Incoming cold water travels
through the dip tube down to the bottom of the water heater. Without the dip tube in place the cold water coming
into the water heater can just travel a short distance to the side and leave
through outlet. The water temperature
will be much lower than normal, and it can seem as though you run out of hot
water very quickly. Cold water entering the heater is sent through
the dip tube to the bottom of the tank where the thermostat is located.
Running even just a gallon out can cause the thermostat, to turn on the gas valve. The pilot light
ignites the gas and the water heater begins heating up the water. The hot water in a water heater tends to form
layers with differing temperatures. When short uses occur frequently the
heater can turn on and off and cause the water at the top of the heater
to keep getting hotter and hotter each time. It’s called “stacking”.
It’s because hot water, like hot air, rises. It can get hot enough to
cause the temperature / pressure safety valve to open and release hot
water from the heater, even with the thermostat setting on low. The safety valve often referred to as a TP valve,
opens to relieve pressure if either the pressure gets too high or the
temperature gets too high. This prevents the water heater from blowing
up if something goes wrong. The TP valve usually is located on the side
of the tank near the top. Normally as your water heater heats the water, the
water expands as it’s heated, and as the water expands some of it gets
pushed back into the source, such as the water main. Sometimes there is
a check valve or some other obstruction between the heater and the
source of cold water. In that case, as the water expands, there is
nowhere for it to go, and thus the pressure begins increasing. If for some reason the TP valve does not open to
relieve the pressure the water heater becomes a bomb and can explode
with amazing power. One way to avoid problems with the T&P valve in this
situation is to install an expansion tank at the inlet. An expansion tank is a pressurized tank usually
with a rubber bladder inside or a diaphragm in the middle. As the water
expands it moves into the expansion tank and doesn’t build up to
dangerous pressure levels. Usually local codes require the outlett of the T&P
valve to be plumbed down to the floor, or outside to the ground, so
no one can get scalded if the valve opens while they are nearby. One of the things that happen when you heat water
is that dissolved minerals in the water can precipitate out and settle
to the bottom. That is what sediment is. You sometimes hear people say
that you shouldn’t drink water that has passed through the water
heater. Obviously if some of the minerals settle out, then the hot
water might have a lower mineral content, but that certainly can’t hurt
you. If it were un-healthy to drink water that has
passed through the heater the NSF or FDA would be advising not to drink
it. There is simply no evidence that it is harmful in any way. Now if
you had lead pipes that would be another story. Hot water could leach
more lead out of the pipes than cold water. If you live in an area with hard water, over time your sediment
can build up to pretty significant levels. If the buildup is large, the amount of water held by the water heater is
reduced, so you could run out of water more quickly. Water heater tanks are internally coated with epoxy
or have a glass lining. This is to prevent rusting and corrosion. To
further fight corrosion water heaters have a magnesium or aluminum rod
called an anode inserted into them from the top. The idea is that the
anode will corrode instead of the tank. Sometimes some anaerobic bacteria can get into the
tank and will react with the magnesium or aluminum forming hydrogen
sulfide gas which is what gives a rotten egg smell. This is more common
with well water than from water mains. Some people say that replacing the magnesium rod,
the more common one, with aluminum can help. There are also some special
(and expensive) anodes that are supposed to solve the problem. Anther
method that works is to sterilize the tank and the hot water pipes with
bleach or hydrogen peroxide. However, the bacteria can come back,
especially if you go away for a time and the water just sits in the
heater for days or weeks. Other than the awful smell the bacteria will
not harm humans. At the bottom of the tank there is a drain valve.
If you live in an area with hard water and you have a sediment problem,
then you should probably replace the cheap plastic drain valve that most
water heaters come with now days with a full flow ball valve. This will
make the tank much easier to drain and flush.